Vacuum Pump V-i125y-R32
Horisontally positioned vacuum gauge, and backstop valve equipped.Capacity: 4,2 m³/h
No supplier
- One-touch operation, easy operation
- Oil-Free Compressor
- Overpressure protection
- Self-emptying function
- Lightweight, portable
(edit with the Customer Reassurance module)
(edit with the Customer Reassurance module)
(edit with the Customer Reassurance module)
Operation is subject to the following refrigerants:
R12, R134a, R401c, R406, R500, R22, R401, R401b, R402b, R407c, R407d, R408, R409a, R411, R411b, R412, R502, R509, R402, R404a, R407a, R407b, R410a, R507, 1234yf, R32
Supply voltage: 110V-120V / 60Hz or 220V-240V / 50 ~ 60Hz
Motor performance: 3 / 4HP
Maximum power consumption: 110V: 8A; 220V: 4A
Maximum discharge pressure: 38,5bar / 3850kPa (558Psi)
Dimensions: 400mmx250mmx355mm
Weight: 13kg
Peel power:
R134a Normal Mode: 1,6 kg / min; Push-Pull: 4,6kg / min
R410a Normal mode: 2,2kg / min; Push-Pull: 6,3kg / min
Horisontally positioned vacuum gauge, and backstop valve equipped.Capacity: 4,2 m³/h
Chilling technicians basic tool kit, complete with 2 adapters. The impact-resistant plastic bag includes: -1 Pieces of copper tube flare VFT-808-M -1 Pieces of copper tube cutters VTC-28B -1 Pieces of copper tube cutters VTC-19 -1 Units manifold VMG-2-R410A -1 Pieces of copper tube deburring VTT-5 -1 Units V01-inch adapter (male thread 5/16 "Hollander +...
For R12, R22, R502, R134a, R404A, R407C, R410a, R600, R123, R290, R32, R 1234yf and others
Refillable 1000ml steel cylinder. Connection: 1/4" SAE Cylinder test pressure: 48Bar
HFO1234yf, R22, R404a, R407c, R134a pressure measuring manometer, -1 ~ 35 Bar
Horisontally positioned vacuum gauge, and backstop valve equipped. Capacity: 11,88 m³/h
Comfort ultra thin wall mounted vertical blow Fan Coil unit. At just 130mm thick and its design makes it ideal for almost any room. The built-in control electronics, the touch button display and the remote controler ensure easy installation and use. Cooling capacity: 3500W Heating capacity: 5250W Dimensions: 1300mm x 130mm x 581mm Net weight: 24 kg
Suitcase contains: 1pcs tube flaring gauge 1pcs Vise with inch grabber (1/4", 5/16", 3/8", 1/2", 5/8", 3/4") 1pcs Vise with metric grabber (6, 8, 10, 12, 15, 16, 18mm)
New Design! Built-in solenoid isolation valve and digital vacuum gauge. Dual Stage vacuum pump. Suitable for R32 and 1234yf.
- One-touch operation, easy operation
- Oil-Free Compressor
- Overpressure protection
- Self-emptying function
- Lightweight, portable